Notice Type
Capacity Constraint

Effective Start Date Time
02/10/2025 7:17 pm

Subject
NGTL Service (USJR IT-R, NEDA FT-D)

Notice Text

NGTL Service (USJR FT-R, NEDA FT-D)

 

USJR: Due to unplanned maintenance on the Hidden Lake North Compressor Station (19998134) and delays with the planned maintenance on the Alces River Compressor Station (19960434), service allowable in  Segments 2, 3, 4, and partial 7 (Upstream of Latornell) will transition from 100% IT-R and 100% FT-R to 0% IT-R and 100% FT-R effective February 10, 2025 at 17:00 MST until further notice. Technicians are on site, actively troubleshooting. At this time, return to service is expected to be within 24 hours. For the purposes of the DOP that will be published today, a placeholder end date of February 11, 2025 will be used until more information is known. An update will be provided at 7:30AM tomorrow morning.

 

WGAT: N/A

 

EGAT: Due to unplanned maintenance on the Hidden Lake North Compressor Station (19998134) and delays with the planned maintenance on the Alces River Compressor Station (19960434), service allowable in segments 6, 10, 11, 13, 14, 15, 16, 17, 23, 24, partial 28 (NEDA) will transition from 100% IT-D and 100% FT-D to 0% IT-D and 69% FT-D effective February 10, 2025 at 17:00 MST until further notice. Technicians are on site and actively troubleshooting. At this time, return to service is expected to be within 24 hours. For the purposes of the DOP that will be published today, a placeholder end date of February 11, 2025 will be used until more information is known. An update will be provided at 7:30AM tomorrow morning.

 

Local Area/Location: N/A

 

New Information

Updated Information

 

Current and upcoming outages

Outage ID

Start

End

 Facility/Outage Name

Facility Type/Scope

Outage Type

Area of Impact

19960434

Feb. 8, 2025

Feb. 10, 2025

Alces River

Compressor Station Maintenance

Planned

USJR, NEDA

19998134

Feb. 10, 2025

TBD

Hidden Lake North

Compressor Station Maintenance

Unplanned

USJR, NEDA

 

Upstream James River Receipt Area

Effective:

February 6, 2025 at 08:00 MST

IT Allowable: 100%

IT-R

IT-S (receipt)

 

 

Expected End:

February 10, 2025 at 17:00 MST

FT Allowable: 100%

FT-R

FT-P

 

 

 

Interconnects:

  Aitken Creek, Big Eddy, Groundbirch East, Gordondale, January Creek

Segments:

  2, 3, 4, 5, 7, partial 8, and partial 9

Effective:

February 10, 2025 at 17:00 MST

IT Allowable: 0%

IT-R

IT-S (receipt)

 

 

Expected End:

Until further notice

FT Allowable: 100%

FT-R

FT-P

 

 

 

Interconnects:

  Aitken Creek, Groundbirch East, Gordondale

Segments:

 Segments 2, 3, 4, and partial 7 (Upstream of Latornell)

 

West Gate Delivery Area

Effective:

July 25, 2024 at 08:00 MST

IT Allowable: 100%

IT-D

 

 

 

 

Expected End:

Until further notice

FT Allowable: 100%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

  Alberta-B.C. Border and Alberta Montana Border

Segments:

 22 and partial 21 (Greater WGAT)

 

East Gate Delivery Area

Effective:

February 6, 2025 at 13:00 MST

IT Allowable: 100%

IT-D

IT-S (delivery)

 

 

Expected End:

February 10, 2025 at 17:00 MST

FT Allowable: 100%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

Aeco C, Carbon, Chancellor, Crossfield East #2, Severn Creek, Empress, McNeil, Unity, Cold Lake, Warwick SE

Segments:

6, 10, 11, 13, 14, 15, 16, 17, 18, 19, 20, 23, 24, partial 21 and partial 28 (Greater EGAT)

Effective:

February 10, 2025 at 17:00 MST

IT Allowable: 0%

IT-D

IT-S (delivery)

 

 

Expected End:

Until further notice

FT Allowable: 69%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

Unity, Cold Lake, Warwick SE                                                                                                                                                 

Segments:

6, 10, 11, 13, 14, 15, 16, 17, 23, 24, and partial 28 (NEDA)

 

Local Area/Location

N/A

 

If there is an overlap between Local Area/Location and Upstream James River Receipt Area, West Gate Delivery Area, or East Gate Delivery Area, then the lower IT Allowable and FT Allowable will be in effect. The details in this bulletin supersede any previously published information and will be reflected and maintained in the next release of the Daily Operating Plan.

NGTL System - Segment Codes & Project Areas Map NGTL System - Operational Areas Map



Notice Type
Capacity Constraint

Effective Start Date Time
02/10/2025 7:17 pm

Subject
NGTL Service (USJR IT-R, NEDA FT-D)

Notice Text

NGTL Service (USJR FT-R, NEDA FT-D)

 

USJR: Due to unplanned maintenance on the Hidden Lake North Compressor Station (19998134) and delays with the planned maintenance on the Alces River Compressor Station (19960434), service allowable in  Segments 2, 3, 4, and partial 7 (Upstream of Latornell) will transition from 100% IT-R and 100% FT-R to 0% IT-R and 100% FT-R effective February 10, 2025 at 17:00 MST until further notice. Technicians are on site, actively troubleshooting. At this time, return to service is expected to be within 24 hours. For the purposes of the DOP that will be published today, a placeholder end date of February 11, 2025 will be used until more information is known. An update will be provided at 7:30AM tomorrow morning.

 

WGAT: N/A

 

EGAT: Due to unplanned maintenance on the Hidden Lake North Compressor Station (19998134) and delays with the planned maintenance on the Alces River Compressor Station (19960434), service allowable in segments 6, 10, 11, 13, 14, 15, 16, 17, 23, 24, partial 28 (NEDA) will transition from 100% IT-D and 100% FT-D to 0% IT-D and 69% FT-D effective February 10, 2025 at 17:00 MST until further notice. Technicians are on site and actively troubleshooting. At this time, return to service is expected to be within 24 hours. For the purposes of the DOP that will be published today, a placeholder end date of February 11, 2025 will be used until more information is known. An update will be provided at 7:30AM tomorrow morning.

 

Local Area/Location: N/A

 

New Information

Updated Information

 

Current and upcoming outages

Outage ID

Start

End

 Facility/Outage Name

Facility Type/Scope

Outage Type

Area of Impact

19960434

Feb. 8, 2025

Feb. 10, 2025

Alces River

Compressor Station Maintenance

Planned

USJR, NEDA

19998134

Feb. 10, 2025

TBD

Hidden Lake North

Compressor Station Maintenance

Unplanned

USJR, NEDA

 

Upstream James River Receipt Area

Effective:

February 6, 2025 at 08:00 MST

IT Allowable: 100%

IT-R

IT-S (receipt)

 

 

Expected End:

February 10, 2025 at 17:00 MST

FT Allowable: 100%

FT-R

FT-P

 

 

 

Interconnects:

  Aitken Creek, Big Eddy, Groundbirch East, Gordondale, January Creek

Segments:

  2, 3, 4, 5, 7, partial 8, and partial 9

Effective:

February 10, 2025 at 17:00 MST

IT Allowable: 0%

IT-R

IT-S (receipt)

 

 

Expected End:

Until further notice

FT Allowable: 100%

FT-R

FT-P

 

 

 

Interconnects:

  Aitken Creek, Groundbirch East, Gordondale

Segments:

 Segments 2, 3, 4, and partial 7 (Upstream of Latornell)

 

West Gate Delivery Area

Effective:

July 25, 2024 at 08:00 MST

IT Allowable: 100%

IT-D

 

 

 

 

Expected End:

Until further notice

FT Allowable: 100%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

  Alberta-B.C. Border and Alberta Montana Border

Segments:

 22 and partial 21 (Greater WGAT)

 

East Gate Delivery Area

Effective:

February 6, 2025 at 13:00 MST

IT Allowable: 100%

IT-D

IT-S (delivery)

 

 

Expected End:

February 10, 2025 at 17:00 MST

FT Allowable: 100%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

Aeco C, Carbon, Chancellor, Crossfield East #2, Severn Creek, Empress, McNeil, Unity, Cold Lake, Warwick SE

Segments:

6, 10, 11, 13, 14, 15, 16, 17, 18, 19, 20, 23, 24, partial 21 and partial 28 (Greater EGAT)

Effective:

February 10, 2025 at 17:00 MST

IT Allowable: 0%

IT-D

IT-S (delivery)

 

 

Expected End:

Until further notice

FT Allowable: 69%

FT-P

FT-D1

FT-D2

STFT

 

Interconnects:

Unity, Cold Lake, Warwick SE                                                                                                                                                 

Segments:

6, 10, 11, 13, 14, 15, 16, 17, 23, 24, and partial 28 (NEDA)

 

Local Area/Location

N/A

 

If there is an overlap between Local Area/Location and Upstream James River Receipt Area, West Gate Delivery Area, or East Gate Delivery Area, then the lower IT Allowable and FT Allowable will be in effect. The details in this bulletin supersede any previously published information and will be reflected and maintained in the next release of the Daily Operating Plan.

NGTL System - Segment Codes & Project Areas Map NGTL System - Operational Areas Map