Tennessee Gas Pipeline Notice 392232
Source LinkAll information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP/TSP Name: 1939164-TENNESSEE GAS PIPELINE | Critical: Y |
Notice Type Desc (1): PIPELINE CONDITIONS | Notice Type Desc (2): CURRENT PIPELINE CONDITIONS |
Notice Eff Date/Time: 09/08/2024 2:46:37PM | Notice End Date/Time: 09/09/2024 9:00:00am |
Post Date/Time: 9/8/2024 2:46:37 PM | Notice ID: 392232 |
Reqrd Rsp: 1 | Rsp Date: 09/08/2024 |
Notice Stat Desc: INITIATE | Prior Notice: |
Subject: RESTRICTIONS FOR 09-09-2024 TIMELY CYCLE |
Effective Timely Cycle (9:00) for the gas day of Monday, September 09, 2024 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ZONES L AND 1 ON THE 500 LINE ONLY FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 2, 3, 4, 5 AND 6 FOR UNDER-TAKES FROM THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 10,000 Dths
· GULFSTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 44% of SOP due to operational concerns; 9,500 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 44% of SIPss due to nominations in excess of operational capacity; 69,093 Dths
SEGMENT RESTRICTIONS
· STA 9 (Segment 109 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 150,159 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to force majeure at STA 860; 10,000 Dths
· MLV 548 (Segment 542 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 17,438 Dths
· STA 204 (Segment 204 BH) - through approx 16% of PIP due to scheduled maintenance and nominations in excess of operational capacity; 267,759 Dths
· STA 219 South (Segment 217 BH) - through 100% of SOP due to operational concerns; 26,361 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 254,182 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 292,571 Dths
· STA 315 (Segment 315 BH) - through approx 67% of SOP due to nominations in excess of operational capacity; 274,136 Dths
· STA 321 (Segment 321 FH) - through approx 30% of SOP due to nominations in excess of operational capacity; 273,681 Dths
· Z5hc North (Segment 299 FH) - through approx 67% of SOP due to nominations in excess of operational capacity; 486,108 Dths
· STA 245 (Segment 245 FH) - through approx 71% of SOP due to nominations in excess of operational capacity; 620,070 Dths
· STA 249 (Segment 249 FH) - through approx 36% of SOP due to nominations in excess of operational capacity; 187,310 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 61,180 Dths
· MLV 273 (Segment 284 FH) - through approx 78% of SOP due to nominations in excess of operational capacity; 169,139 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will not accept nominations for FSAO injections at all storage fields.
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
TSP/TSP Name: 1939164-TENNESSEE GAS PIPELINE | Critical: Y |
Notice Type Desc (1): PIPELINE CONDITIONS | Notice Type Desc (2): CURRENT PIPELINE CONDITIONS |
Notice Eff Date/Time: 09/08/2024 2:46:37PM | Notice End Date/Time: 09/09/2024 9:00:00am |
Post Date/Time: 9/8/2024 2:46:37 PM | Notice ID: 392232 |
Reqrd Rsp: 1 | Rsp Date: 09/08/2024 |
Notice Stat Desc: INITIATE | Prior Notice: |
Subject: RESTRICTIONS FOR 09-09-2024 TIMELY CYCLE |
Effective Timely Cycle (9:00) for the gas day of Monday, September 09, 2024 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ZONES L AND 1 ON THE 500 LINE ONLY FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 2, 3, 4, 5 AND 6 FOR UNDER-TAKES FROM THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 10,000 Dths
· GULFSTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 44% of SOP due to operational concerns; 9,500 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 44% of SIPss due to nominations in excess of operational capacity; 69,093 Dths
SEGMENT RESTRICTIONS
· STA 9 (Segment 109 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 150,159 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to force majeure at STA 860; 10,000 Dths
· MLV 548 (Segment 542 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 17,438 Dths
· STA 204 (Segment 204 BH) - through approx 16% of PIP due to scheduled maintenance and nominations in excess of operational capacity; 267,759 Dths
· STA 219 South (Segment 217 BH) - through 100% of SOP due to operational concerns; 26,361 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 254,182 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 292,571 Dths
· STA 315 (Segment 315 BH) - through approx 67% of SOP due to nominations in excess of operational capacity; 274,136 Dths
· STA 321 (Segment 321 FH) - through approx 30% of SOP due to nominations in excess of operational capacity; 273,681 Dths
· Z5hc North (Segment 299 FH) - through approx 67% of SOP due to nominations in excess of operational capacity; 486,108 Dths
· STA 245 (Segment 245 FH) - through approx 71% of SOP due to nominations in excess of operational capacity; 620,070 Dths
· STA 249 (Segment 249 FH) - through approx 36% of SOP due to nominations in excess of operational capacity; 187,310 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 61,180 Dths
· MLV 273 (Segment 284 FH) - through approx 78% of SOP due to nominations in excess of operational capacity; 169,139 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will not accept nominations for FSAO injections at all storage fields.
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.