TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  11/09/2024 3:13:24PM Notice End Date/Time:  11/10/2024 9:00:00am
Post Date/Time:  11/9/2024 3:13:24 PM Notice ID: 392765
Reqrd Rsp:  1 Rsp Date:  11/09/2024
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 11-10-2024 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of Sunday, November 10, 2024 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONE 0, ZONE 1 ON THE 100 LINE, ALL OF ZONES 2, 3, 4, 5 AND 6 FOR UNDER-TAKES OUT OF THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

METER RESTRICTIONS

·         WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 2% of SA due to operational concerns; 1,823 Dths

·         Tres PAL/TGP Tres Palacios Storage: Receipt Meter (Pin 421055) - through 100% of SIPss due to imbalance management quantity exceeded; 188,559 Dths

·         TRNSCO/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths

·         AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 52% of SIPss due to nominations in excess of operational capacity; 69,565 Dths

·         EGTS/TGP Harrison Injection Potter Receipt Meter (Pin 460004) - through 100% of IT due to operational concerns; 143,198 Dths

SEGMENT RESTRICTIONS

·         STA 860 (Segment 860 BH) - through 100% of SOP due to force majeure at STA 860; 10,000 Dths

·         STA 87 South 800 Line (Segment 860 BH) - through 100% of SOP due to operational concerns; 22,200 Dths

·         MLV 548 (Segment 542 BH) - through 100% of IT due to scheduled maintenance and nominations in excess of operational capacity; 19,826 Dths

·         STA 110 South (Segment 187 BH) - through 100% of SOP due to operational concerns; 9,982 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 260,380 Dths

·         MLV 314 East (Segment 314 BH) - through approx 55% of SOP due to nominations in excess of operational capacity; 178,127 Dths

·         STA 315 (Segment 315 BH) - through approx 47% of SOP due to nominations in excess of operational capacity; 198,100 Dths

·         STA 321 (Segment 321 FH) - through approx 38% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 356,682 Dths

·         STA 230B -Niagara Spur North (Segment 296 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 11,000 Dths

·         Z5 HC North (Segment 299 FH) - through approx 83% of SOP due to nominations in excess of operational capacity; 603,563 Dths

·         STA 245 (Segment 245 FH) - through approx 73% of SOP due to nominations in excess of operational capacity; 633,762 Dths

·         STA 249 (Segment 249 FH) - through approx 50% of SOP due to nominations in excess of operational capacity; 260,982 Dths

·         MLV 273 (Segment 284 FH) - through approx 72% of SOP due to nominations in excess of operational capacity; 167,846 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only if operationally feasible.

 

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will not accept nominations for FSAO injections at all storage fields.

 

Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  11/09/2024 3:13:24PM Notice End Date/Time:  11/10/2024 9:00:00am
Post Date/Time:  11/9/2024 3:13:24 PM Notice ID: 392765
Reqrd Rsp:  1 Rsp Date:  11/09/2024
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 11-10-2024 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of Sunday, November 10, 2024 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONE 0, ZONE 1 ON THE 100 LINE, ALL OF ZONES 2, 3, 4, 5 AND 6 FOR UNDER-TAKES OUT OF THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

METER RESTRICTIONS

·         WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 2% of SA due to operational concerns; 1,823 Dths

·         Tres PAL/TGP Tres Palacios Storage: Receipt Meter (Pin 421055) - through 100% of SIPss due to imbalance management quantity exceeded; 188,559 Dths

·         TRNSCO/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths

·         AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 52% of SIPss due to nominations in excess of operational capacity; 69,565 Dths

·         EGTS/TGP Harrison Injection Potter Receipt Meter (Pin 460004) - through 100% of IT due to operational concerns; 143,198 Dths

SEGMENT RESTRICTIONS

·         STA 860 (Segment 860 BH) - through 100% of SOP due to force majeure at STA 860; 10,000 Dths

·         STA 87 South 800 Line (Segment 860 BH) - through 100% of SOP due to operational concerns; 22,200 Dths

·         MLV 548 (Segment 542 BH) - through 100% of IT due to scheduled maintenance and nominations in excess of operational capacity; 19,826 Dths

·         STA 110 South (Segment 187 BH) - through 100% of SOP due to operational concerns; 9,982 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 260,380 Dths

·         MLV 314 East (Segment 314 BH) - through approx 55% of SOP due to nominations in excess of operational capacity; 178,127 Dths

·         STA 315 (Segment 315 BH) - through approx 47% of SOP due to nominations in excess of operational capacity; 198,100 Dths

·         STA 321 (Segment 321 FH) - through approx 38% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 356,682 Dths

·         STA 230B -Niagara Spur North (Segment 296 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 11,000 Dths

·         Z5 HC North (Segment 299 FH) - through approx 83% of SOP due to nominations in excess of operational capacity; 603,563 Dths

·         STA 245 (Segment 245 FH) - through approx 73% of SOP due to nominations in excess of operational capacity; 633,762 Dths

·         STA 249 (Segment 249 FH) - through approx 50% of SOP due to nominations in excess of operational capacity; 260,982 Dths

·         MLV 273 (Segment 284 FH) - through approx 72% of SOP due to nominations in excess of operational capacity; 167,846 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only if operationally feasible.

 

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will not accept nominations for FSAO injections at all storage fields.

 

Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.