Tennessee Gas Pipeline Notice 394146

Source Link

All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  03/26/2025 7:33:54PM Notice End Date/Time:  03/27/2025 9:00:00am
Post Date/Time:  3/26/2025 7:33:54 PM Notice ID: 394146
Reqrd Rsp:  1 Rsp Date:  03/26/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 03-26-2025 ID3
Notice Text:

Effective Intraday 3 Cycle (22:00) for the gas day of Wednesday, March 26, 2025 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

NONE

 

 

 

METER RESTRICTIONS

·         GDR/TGP Rio Bravo Hidalgo Delivery Meter (Pin 421017) - through approx 84% of IT increases deliveries due to location off rate; 5,853 Dths

·         Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 5,000 Dths

·         TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths

SEGMENT RESTRICTIONS

·         MLV 406 (Segment 406 BH) - through 100% of PIP increases due to scheduled maintenance and nominations in excess of operational capacity; 4,982 Dths

·         STA 40 South Of Carthage (Segment 132 FH) - through 100% of SOP increases due to emergent repair at STA 40; 10,664 Dths

·         MLV 314 East (Segment 314 BH) - through approx 28% of SOP increases due to nominations in excess of operational capacity; 19,778 Dths

·         STA 245 (Segment 245 FH) - through approx 92% of SOP increases due to nominations in excess of operational capacity; 63,927 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only if operationally feasible.

 

 

 

STORAGE RESTRICTIONS

NONE

 

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  03/26/2025 7:33:54PM Notice End Date/Time:  03/27/2025 9:00:00am
Post Date/Time:  3/26/2025 7:33:54 PM Notice ID: 394146
Reqrd Rsp:  1 Rsp Date:  03/26/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 03-26-2025 ID3
Notice Text:

Effective Intraday 3 Cycle (22:00) for the gas day of Wednesday, March 26, 2025 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

NONE

 

 

 

METER RESTRICTIONS

·         GDR/TGP Rio Bravo Hidalgo Delivery Meter (Pin 421017) - through approx 84% of IT increases deliveries due to location off rate; 5,853 Dths

·         Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 5,000 Dths

·         TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths

SEGMENT RESTRICTIONS

·         MLV 406 (Segment 406 BH) - through 100% of PIP increases due to scheduled maintenance and nominations in excess of operational capacity; 4,982 Dths

·         STA 40 South Of Carthage (Segment 132 FH) - through 100% of SOP increases due to emergent repair at STA 40; 10,664 Dths

·         MLV 314 East (Segment 314 BH) - through approx 28% of SOP increases due to nominations in excess of operational capacity; 19,778 Dths

·         STA 245 (Segment 245 FH) - through approx 92% of SOP increases due to nominations in excess of operational capacity; 63,927 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only if operationally feasible.

 

 

 

STORAGE RESTRICTIONS

NONE

 

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.