Natural Gas Pipeline Notice 45709

Source Link

All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.

TSP/TSP Name:  6931794-NATURAL GAS PIPELINE CO. Critical: Y
Notice Type Desc (1):  OPERATIONAL ALERT Notice Type Desc (2):  ADVISORY/DIRECTIONAL NOTICE
Notice Eff Date/Time:  01/14/2025 4:22:51PM Notice End Date/Time:  02/28/2025 9:00:00am
Post Date/Time:  1/14/2025 4:22:51 PM Notice ID: 45709
Reqrd Rsp:  1 Rsp Date:  01/14/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  HOURLY TAKES ADVISORY - MARKET DELIVERY
Notice Text:

HOURLY TAKES ADVISORY – MARKET DELIVERY ZONE

 

Due to the impending colder weather and current system operating conditions, effective for Saturday, January 18, 2025, at 9:00 am., and continuing until further notice, per Natural's tariff [GT&C Section 7.4], Shippers and Point Operators are advised to limit hourly takes at ALL DELIVERY POINTS IN THE MARKET DELIVERY ZONE.  Additionally, Natural continues to monitor operating conditions system wide.  If necessary, Natural will issue additional Operational Flow Orders (OFOs) to address Shipper actions that are detrimental to such operating conditions outside the Market Delivery Zone.  Should Natural's ability to provide hourly flexibility decrease, an Operational Flow Order (OFO) condition will occur.

 

As provided in the tariff, at each point in the Market Delivery Zone, the hourly rights for each Shipper/Point Operator will be limited.  Such hourly rights will be limited by service priority and nomination cycle, based on hours remaining in the gas day.  Shippers and Point Operators are responsible for calculating and monitoring their hourly usage so as not to exceed the limits described herein.

 

Hourly Rights for Firm Service – 150%

Includes Primary and Secondary Confirmed Nominations and Unused No-Notice firm service rights

 

            Timely/Evening Cycles

Limited to 6.25% (150% / 24 hours) of Firm Service. 

 

Intra-Day 1 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service; plus 7.895% (150% / 19 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service. 

 

Intra-Day 2 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service; plus 10.00% (150% / 15 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service. 

 

Intra-Day 3 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service, plus 13.64% (150% / 11 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service.

 

 

Hourly Rights for Interruptible Service – 105%

Includes Interruptible and AOR nominations, as well as POA tolerances

 

Timely/Evening Cycles

Limited to 4.375% (105% / 24 hours) of Interruptible Service. 

 

Intra-Day 1 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 5.53% (105% / 19 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service. 

 

 

Intra-Day 2 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 7.0% (105% / 15 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service. 

 

Intra-Day 3 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 9.55% (105% / 11 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service.

 

Limitation on Nominations in All Cycles for Firm and Interruptible Service

 

Shippers are advised that nominations should be received by Timely/Evening Cycle in order to utilize full rights over 24 hours, to avoid exceeding the 24 hour ratable hourly takes calculation.  In all cases, any first time nominations received on Non-Timely Cycles for full MDQ utilization rights, plus any scheduled ITS nominations must conform to the 24 hour ratable calculation.  Shipper's hourly rights based on firm MDQ, plus interruptible nominations, must be adequate enough to accommodate the calculated hourly rights for the remaining hours of the gas day.  Specifically, hourly rights cannot exceed 150% / 24 hours of Shipper's MDQ on the nominated contract, plus 105% / 24 hours of Shipper's interruptible nominations.

 

In addition, Natural would like to remind point operators to utilize the Operator Point Reports available on our website to assist you in monitoring your hourly takes.  These reports are available by linking to http://pipeline.kindermorgan.com.  Select NGPL > Customer Activities > Log On > Flowing Gas > Additional Reports > NGPL/HRZ > NGPL/HRZ – Hourly Nomination Details.

 

Please contact your Account Director or Scheduling Representative if you have any questions.

TSP/TSP Name:  6931794-NATURAL GAS PIPELINE CO. Critical: Y
Notice Type Desc (1):  OPERATIONAL ALERT Notice Type Desc (2):  ADVISORY/DIRECTIONAL NOTICE
Notice Eff Date/Time:  01/14/2025 4:22:51PM Notice End Date/Time:  02/28/2025 9:00:00am
Post Date/Time:  1/14/2025 4:22:51 PM Notice ID: 45709
Reqrd Rsp:  1 Rsp Date:  01/14/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  HOURLY TAKES ADVISORY - MARKET DELIVERY
Notice Text:

HOURLY TAKES ADVISORY – MARKET DELIVERY ZONE

 

Due to the impending colder weather and current system operating conditions, effective for Saturday, January 18, 2025, at 9:00 am., and continuing until further notice, per Natural's tariff [GT&C Section 7.4], Shippers and Point Operators are advised to limit hourly takes at ALL DELIVERY POINTS IN THE MARKET DELIVERY ZONE.  Additionally, Natural continues to monitor operating conditions system wide.  If necessary, Natural will issue additional Operational Flow Orders (OFOs) to address Shipper actions that are detrimental to such operating conditions outside the Market Delivery Zone.  Should Natural's ability to provide hourly flexibility decrease, an Operational Flow Order (OFO) condition will occur.

 

As provided in the tariff, at each point in the Market Delivery Zone, the hourly rights for each Shipper/Point Operator will be limited.  Such hourly rights will be limited by service priority and nomination cycle, based on hours remaining in the gas day.  Shippers and Point Operators are responsible for calculating and monitoring their hourly usage so as not to exceed the limits described herein.

 

Hourly Rights for Firm Service – 150%

Includes Primary and Secondary Confirmed Nominations and Unused No-Notice firm service rights

 

            Timely/Evening Cycles

Limited to 6.25% (150% / 24 hours) of Firm Service. 

 

Intra-Day 1 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service; plus 7.895% (150% / 19 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service. 

 

Intra-Day 2 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service; plus 10.00% (150% / 15 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service. 

 

Intra-Day 3 Cycle

Limited to the hourly rights computed in the previous cycle for Firm Service, plus 13.64% (150% / 11 hours) of the difference of current cycle Firm Service minus prior cycle Firm Service.

 

 

Hourly Rights for Interruptible Service – 105%

Includes Interruptible and AOR nominations, as well as POA tolerances

 

Timely/Evening Cycles

Limited to 4.375% (105% / 24 hours) of Interruptible Service. 

 

Intra-Day 1 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 5.53% (105% / 19 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service. 

 

 

Intra-Day 2 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 7.0% (105% / 15 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service. 

 

Intra-Day 3 Cycle

Limited to the hourly rights computed in the previous cycle for Interruptible Service; plus 9.55% (105% / 11 hours) of the difference of current cycle Interruptible Service minus prior cycle Interruptible Service.

 

Limitation on Nominations in All Cycles for Firm and Interruptible Service

 

Shippers are advised that nominations should be received by Timely/Evening Cycle in order to utilize full rights over 24 hours, to avoid exceeding the 24 hour ratable hourly takes calculation.  In all cases, any first time nominations received on Non-Timely Cycles for full MDQ utilization rights, plus any scheduled ITS nominations must conform to the 24 hour ratable calculation.  Shipper's hourly rights based on firm MDQ, plus interruptible nominations, must be adequate enough to accommodate the calculated hourly rights for the remaining hours of the gas day.  Specifically, hourly rights cannot exceed 150% / 24 hours of Shipper's MDQ on the nominated contract, plus 105% / 24 hours of Shipper's interruptible nominations.

 

In addition, Natural would like to remind point operators to utilize the Operator Point Reports available on our website to assist you in monitoring your hourly takes.  These reports are available by linking to http://pipeline.kindermorgan.com.  Select NGPL > Customer Activities > Log On > Flowing Gas > Additional Reports > NGPL/HRZ > NGPL/HRZ – Hourly Nomination Details.

 

Please contact your Account Director or Scheduling Representative if you have any questions.